2 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump System RP14AY24AJ2NA, RH2TY2417STANNJ

Original price was: $3,350.00.Current price is: $335.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
56 People watching this product now!
Description

2 Ton Rheem 14.3 SEER2 R-454B Two Stage Heat Pump System RP14AY24AJ2NA, RH2TY2417STANNJ

Two-stage operation starts here. The RP14AY24AJ2NA outdoor heat pump and RH2TY2417STANNJ air handler form a 24,000 BTU R-454B split system that runs on low stage the vast majority of the year and only steps to high stage on design days. Longer, gentler run cycles mean tighter temperature control, quieter operation and noticeably better humidity removal than a single-stage unit of the same capacity, which is why this is the most-requested size for smaller Florida homes and townhouses.

Is a 2 Ton Heat Pump System the Right Size?

At 24,000 BTU per hour, a 2 ton heat pump generally serves 900 to 1,200 square feet of conditioned area. Two-bedroom townhouses, small ranch homes, coastal cottages and well-insulated slab houses commonly land in this range. The load calculation, not the floor plan, determines whether 2 tons is correct.

Duct leakage, attic R-value, single versus double pane glass, shading, and the direction the largest windows face can swing the calculated load by half a ton in either direction. With a two-stage compressor there is also less penalty for being slightly generous on capacity, because low stage runs at roughly two-thirds output and keeps cycle lengths long, but a system that is a full ton oversized will still leave the house cool and damp.

Ideal for: Two-bedroom townhomes, small single-story homes, beach cottages, duplex units and finished basements in the 900 to 1,200 square foot range.

Need more capacity? Step up to the 2.5 Ton Rheem RP14AY30AJ2NA, RH2TY3617STANNJ Heat Pump System, which adds 6,000 BTU and a larger indoor coil while keeping the same 17.5 in. cabinet width.

Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Heat Pump RP14AY24AJ2NA – 2 Ton / 24,000 BTU Two-Stage Heat Pump
Indoor Air Handler RH2TY2417STANNJ – 17.5 in. Wide Multiposition Air Handler
Application Residential Split System Heat Pump, Heating and Cooling
Refrigerant R-454B Low GWP (A2L)
Compressor Two-Stage Scroll
Rated Efficiency 14.3 SEER2 / 9.0 EER2 / 7.5 HSPF2 (Region IV)
AHRI Reference 214568762
Condenser Electrical 208/230V, Single Phase, 60 Hz – 16 MCA / 25 A Max Fuse or Breaker
Air Handler Electrical 208/240V, Single Phase, 60 Hz
Line Set Connections 3/8 in. Liquid, 3/4 in. Vapor

This is a matched AHRI-certified pair, not a mix-and-match assembly. The two-stage compressor in the RP14AY24AJ2NA talks to the constant-torque blower in the RH2TY2417STANNJ so airflow drops with capacity on low stage. Finish the installation with a weatherproof electrical whip and 60 amp pull-out disconnect at the outdoor unit.

Condenser & Air Handler Features

RP14AY24AJ2NA Outdoor Heat Pump

  • Two-stage scroll compressor with high and low speeds for precise temperature control
  • Low stage operation lowers indoor humidity compared with single-stage compressors of equal capacity
  • Inverted reversing valve shifts with gravity assist for faster, lower-stress heat mode changeover
  • PlusOne Expanded Valve Space with 3 in. to 5 in. of service valve clearance
  • PlusOne Triple Service Access: 15 in. corner opening plus individual louver panels
  • Integrated PlusOne Refrigerant Detection System on a single sensor and mitigation board
  • Simplified wiring and commissioning versus multi-component A2L detection designs
  • Works with any standard 24V thermostat, including two-stage heat pump controls
  • R-454B refrigerant carries a 78 percent lower GWP than previous generation refrigerants
  • 16 amp minimum circuit ampacity on 208/230V single phase power

RH2TY2417STANNJ Air Handler

  • Matched 17.5 in. cabinet keeps the footprint identical to the 1.5 ton system for closet retrofits
  • Constant-torque ECM motor holds airflow steady as filters load and duct static rises
  • Two-stage airflow tracks the compressor’s high and low stages
  • Upflow, downflow, horizontal left and horizontal right conversion in the field
  • All-aluminum A-coil with internally grooved tubing resists coastal corrosion
  • 1.0 in. foil-faced insulation keeps blower noise out of adjacent living space
  • Tested to less than 2 percent cabinet air leakage at 1 in. H2O per ASHRAE Standard 193
  • Heavy-gauge steel cabinet supports horizontal attic mounting on a platform or hangers
  • Field-installed RXBH heat kits include UL and cUL listed breakers for service disconnect
  • Factory-installed A2L sensor pauses the outdoor unit if refrigerant is detected indoors

Specifications & Manuals

RP14AY Technical Specifications Rheem RP14AY Brochure Rheem RP14AY RP15AY Installation Instructions Rheem RP14AY Submittal RH2TY Technical Specifications Rheem RH2TY RH1P Installation Instructions Rheem RH2TY Submittal Rheem Warranty

Complete literature for both halves of this package is provided here: rating and performance tables, submittal sheets for permit and bid packages, full installation instructions for the outdoor unit and air handler, product brochure, and Rheem warranty terms. Submittal sheets are the fastest reference for dimensions, clearances and electrical data.