2 Ton Goodman 14.5 SEER2 R32 Central A/C Wall Mount Split System GLXS4BA2410, AWST24SU13 Apartment/Condo Type Air Handler

Original price was: $3,036.00.Current price is: $303.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
43 People watching this product now!
Description

2 Ton Goodman 14.5 SEER2 R32 Central A/C Wall Mount Split System GLXS4BA2410, AWST24SU13 Apartment/Condo Type Air Handler

This system delivers 24,000 BTU/h of cooling in the same small-chassis wall closet footprint as the 1.5 ton model. It pairs the GLXS4BA2410 R-32 condenser with the AWST24SU13 wall-mount air handler (AHRI #215214931, 14.5 SEER2). It’s made for two-bedroom apartments, larger condos and townhome units with a recessed or wall-hung air handler. Heat is available up to 10 kW factory pre-installed. The AWST24SU13 includes a refrigerant detection system that shuts off the cooling call, runs the blower and turns off electric heat if it senses an R-32 leak. It’s a strong fit for landlords, HOAs and contractors upgrading multifamily units to R-32.

Is a 2 Ton Air Conditioning System the Right Size?

Two tons (24,000 BTU/h) typically fits two-bedroom apartments, larger condos and small townhomes, often around 900-1,200 sq. ft. as a general reference. Units on upper floors, units with large sliding doors or corner exposure, and open kitchen-living layouts usually need more capacity than interior units of the same size.

In multifamily buildings, shared walls reduce heat gain, while roof exposure and west-facing glass increase it. If the existing wall mount system short-cycles or leaves the unit clammy, it may be oversized. A load calculation will show whether 1.5 or 2 tons is the better fit.

Ideal for: Two-bedroom apartments, larger condos, townhome units and multifamily properties with in-wall air handler closets.

Need more capacity? Step up to the 2.5 Ton Goodman 15.2 SEER2 R32 Central Wall Mount System GLXS4BA3010, AWST30LU13 for larger units.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit GLXS4BA2410 – 2 Ton R32 Split System Air Conditioner
Indoor Air Handler AWST24SU13 Wall-Mount Air Handler (Small Chassis, 20.2″ Cabinet)
Application Apartment/Condo Wall Mount Cooling System (Factory Electric Heat Optional)
Refrigerant R-32
Compressor Single-Stage Rotary Compressor with Advanced Copeland Technology
Metering Device Factory-Installed Thermal Expansion Valve (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit – 10.9 MCA / 15A Max Overcurrent
Air Handler Electrical 208/230V, Single Phase – See Rating Plate (Varies with Heat Option)

The GLXS4BA2410 condenser shares the compact 26″ x 26″ x 27″ cabinet of the 1.5 ton, so it swaps into the same balcony or ground-level pad. The AWST24SU13 air handler keeps the small chassis, a 14″ x 18″ x 1″ filter and front or bottom return. It offers factory heat options of 5 kW, 8 kW or 10 kW. Browse more indoor options in our wall mount and vertical air handlers category. If heat pump heating makes more sense for your building, see the 2 ton Goodman R32 heat pump wall mount system.

Condensing Unit & Air Handler Features

GLXS4BA2410 Outdoor Condensing Unit

  • 24,000 BTU/h nominal cooling capacity
  • Single-stage rotary compressor with Advanced Copeland Technology
  • Same compact 26″ x 26″ x 27″ cabinet as the 1.5 ton
  • 74 dBA rated sound level
  • 53 oz. factory R-32 charge for 15 ft. of tubing
  • 3/8″ liquid and 3/4″ suction line connections
  • Enclosed contactor and extended-life capacitors
  • Steel louver coil guard and wire fan discharge grille
  • Top and side maintenance access
  • Anchor bracket kits available for hurricane-wind installations

AWST24SU13 Wall-Mount Air Handler

  • Refrigerant detection system for R-32 leak mitigation
  • Recessed or wall-hung vertical upflow installation
  • Small chassis with front or bottom return
  • Factory-installed pull-type disconnect
  • Built-in filter rack, 14″ x 18″ x 1″ filter included
  • Direct-drive, multi-speed motor with five speed taps
  • Cabinet air leakage under 2.0% at 1.0″ H₂O (ASHRAE 193)
  • Thermoplastic drain pan with bottom primary and secondary drains
  • 4″ fresh air knockouts on both sides
  • Factory pre-installed 5 kW, 8 kW or 10 kW heat available

Specifications & Manuals

GLXS4B Technical Specifications GLXS4 GLXS5 Installation Manual AWST Technical Specifications AWST R32 Installation Manual AWST Warranty Certificate GLSX GLZS Warranty Certificate

Documentation covers GLXS4BA2410 condenser data, AWST24SU13 airflow by speed tap, R-32 mitigation requirements, wiring, installation steps and warranty terms for both components.