2.5 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump System RP14AY30AJ2NA, RH2TY3617STANNJ

Original price was: $3,640.00.Current price is: $364.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
16 People watching this product now!
Description

2.5 Ton Rheem 14.3 SEER2 R-454B Two Stage Heat Pump System RP14AY30AJ2NA, RH2TY3617STANNJ

This 30,000 BTU Rheem heat pump package moves up to the RH2TY3617STANNJ air handler, a three-ton-class coil in a 17.5 inch cabinet, paired with the two-stage RP14AY30AJ2NA outdoor unit. The combination is deliberately coil-heavy: more evaporator face area with a 2.5 ton compressor produces a lower sensible heat ratio, which is exactly what a humid climate needs. Homeowners get the dehumidification benefit without giving up the narrow closet footprint.

Is a 2.5 Ton Heat Pump System the Right Size?

A 2.5 ton system covers roughly 1,100 to 1,500 square feet in most of the Sun Belt. It is a frequent answer for three-bedroom ranch homes, mid-size townhouses and 1990s-era tract houses that have had attic insulation or windows upgraded since the original system was installed.

This capacity is also where many homes sit between two nominal sizes. When a Manual J calculation lands between 24,000 and 30,000 BTU, the 2.5 ton two-stage unit is usually the safer pick, because low stage covers the lighter part of the season without the short cycling that an oversized single-stage unit produces. Verify that the existing duct system can carry the airflow before upsizing from a 2 ton.

Ideal for: Three-bedroom ranch homes, larger townhomes, renovated tract houses, and open-plan homes in the 1,100 to 1,500 square foot range.

Need more capacity? Step up to the 3 Ton Rheem RP14AY36AJ2NA, RH2TY3617STANNJ Heat Pump System, which uses the identical air handler with a larger outdoor unit.

Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Heat Pump RP14AY30AJ2NA – 2.5 Ton / 30,000 BTU Two-Stage Heat Pump
Indoor Air Handler RH2TY3617STANNJ – 17.5 in. Wide Multiposition Air Handler
Application Residential Split System Heat Pump, Heating and Cooling
Refrigerant R-454B Low GWP (A2L)
Compressor Two-Stage Scroll
Rated Efficiency 14.3 SEER2 / 9.0 EER2 / 7.5 HSPF2 (Region IV)
AHRI Reference 214568766
Condenser Electrical 208/230V, Single Phase, 60 Hz – 20 MCA / 30 A Max Fuse or Breaker
Air Handler Electrical 208/240V, Single Phase, 60 Hz
Line Set Connections 3/8 in. Liquid, 3/4 in. Vapor

The RH2TY3617STANNJ steps the blower up to a larger constant-torque ECM motor than the 2417 cabinet uses, so it has the static pressure headroom for longer duct runs and higher-MERV filtration. Mount the outdoor unit on a 40 x 40 Cladlite hurricane condenser pad to keep it level and above standing water.

Condenser & Air Handler Features

RP14AY30AJ2NA Outdoor Heat Pump

  • 30,000 BTU two-stage scroll compressor with independent high and low capacity
  • Low stage carries mild-weather load for longer cycles and steadier room temperatures
  • Gravity-assisted inverted reversing valve reduces joint stress during defrost cycles
  • 27 square inch minimum service valve working area from PlusOne Expanded Valve Space
  • Removable two-fastener corner panel opens a 15 in. wide diagnostic and repair area
  • One-box PlusOne Refrigerant Detection System with integrated A2L sensor
  • Outdoor unit operation pauses automatically if excess refrigerant is sensed
  • Louvered coil guard protects the condenser from yard debris and string trimmers
  • R-454B platform meets the EPA’s 2025 GWP limit of 700 for residential HVAC
  • 20 amp minimum circuit ampacity, 30 amp maximum overcurrent protection

RH2TY3617STANNJ Air Handler

  • Three-ton-class coil in a 17.5 in. wide cabinet for high capacity in a narrow closet
  • Larger constant-torque ECM blower than the 2417 cabinet for added external static capability
  • Extra coil face area with a 2.5 ton compressor improves latent moisture removal
  • Convertible to upflow, downflow, horizontal left or horizontal right without a conversion kit
  • Aluminum fin and internally grooved aluminum tube coil construction
  • Foil-faced 1.0 in. insulation controls sweating and blower noise
  • Under 2 percent cabinet leakage at 1 in. H2O, tested to ASHRAE Standard 193
  • Accepts higher-capacity RXBH electric heat kits than the 17.5 in. two-ton cabinet
  • Factory-provided knockouts simplify electrical, condensate and line set routing
  • Integrated A2L refrigerant detection wired to shut down the system on a leak event

Specifications & Manuals

RP14AY Technical Specifications Rheem RP14AY Brochure Rheem RP14AY RP15AY Installation Instructions Rheem RP14AY Submittal RH2TY Technical Specifications Rheem RH2TY RH1P Installation Instructions Rheem RH2TY Submittal Rheem Warranty

The documents above cover equipment selection through startup: technical specifications with capacity and airflow tables, submittal sheets for dimensions and electrical data, installation instructions for both the condenser and the air handler, the RP14AY product brochure, and Rheem warranty terms. The RH2TY documents also contain the electric heat kit selection tables.