2.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY30AJ1NA, RH2TY3617STANNJ

Original price was: $3,510.00.Current price is: $351.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
42 People watching this product now!
Description

2.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY30AJ1NA, RH2TY3617STANNJ

At 30,000 BTU and 15.2 SEER2, this Rheem Endeavor Line package sits in the middle of the residential range and solves a problem homeowners hit constantly: needing more than 2 tons without the wider indoor cabinet that usually comes with it. The RA14AY30AJ1NA condenser is matched to the RH2TY3617STANNJ air handler – a 36-size coil in a 17.5-inch chassis – under AHRI reference 215232493. For a retrofit where the closet is fixed and the load calculation came back at 2.5 tons, this is the combination that fits.

Is a 2.5 Ton Refrigeration System the Right Size?

Thirty thousand BTU per hour typically serves 1,200 to 1,500 square feet in a hot, humid climate. This is the size that frequently shows up on three-bedroom ranch homes, older Florida block construction with moderate insulation, and 1,300 square foot homes that have added attic insulation or impact windows since the original system was installed.

The half-ton steps matter more than people expect. A home that has been re-roofed with radiant barrier or had its ductwork sealed can legitimately drop from 3 tons to 2.5 without losing comfort, and the smaller system will hold humidity better because it runs longer cycles. Conversely, adding conditioned square footage or replacing shade trees often pushes a 2.5 ton home into 3 ton territory. Confirm with a load calculation rather than matching the old nameplate.

Ideal for: Three-bedroom ranch homes, mid-size single-story houses, well-insulated 1,400 square foot homes, and retrofits where the existing closet cannot be widened.

Need more capacity? Step up to the 3 Ton Rheem 15.2 SEER2 R454B System RA14AY36AJ1NA, RH2TY3617STANNJ, which uses this exact air handler with a larger outdoor unit.

Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, duct design, window area, ceiling height, occupancy, and local design conditions. Run our AC tonnage and BTU calculator, request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit RA14AY30AJ1NA – 2.5 Ton Endeavor Line Classic Series Air Conditioner
Indoor Air Handler RH2TY3617STANNJ Two-Stage Multiposition Air Handler
Application Residential Split System, Cool Only with Field-Installed Electric Heat
Refrigerant R-454B
Nominal Capacity 30,000 BTU / 2.5 Tons
Rated Efficiency 15.2 SEER2
Air Handler Cabinet Width 17.5 inches
AHRI Reference Number 215232493
Electrical 208-230V, Single Phase, 60 Hz

The RH2TY3617STANNJ is the largest coil Rheem builds into the narrow 17.5-inch cabinet, and it steps the blower up to a 1/2 HP constant torque ECM motor. That extra motor capacity is what allows a 2.5 or 3 ton load to be served without moving to a 21-inch chassis. Electric heat kits, line sets, and controls are ordered separately.

Condensing Unit & Air Handler Features

RA14AY30AJ1NA Outdoor Condensing Unit

  • 2.5 ton nominal capacity rated at 15.2 SEER2
  • Built for low-GWP R-454B refrigerant under the 2025 EPA GWP limit
  • 7mm condenser coil lowers refrigerant charge and unit weight
  • PlusOne Triple Service Access with 15-inch corner service opening
  • Two-fastener removable corner speeds diagnostics
  • Patented one-box PlusOne Refrigerant Detection System
  • Pauses outdoor operation automatically on excess refrigerant detection
  • Curved louvered panels shield the coil from yard debris and impact
  • Corrosion-resistant composite base pan with powder coat finish
  • 10-year conditional parts warranty with Rheem registration

RH2TY3617STANNJ Air Handler

  • Serves 2.5 and 3 ton applications in a 17.5-inch cabinet
  • 1/2 HP constant torque ECM blower motor
  • Two-stage airflow for longer, quieter dehumidification cycles
  • 1.0 inch foil-faced cabinet insulation
  • Aluminum fins bonded to internally grooved aluminum tubing
  • Factory-installed TXV matched to R-454B operation
  • 4-way convertible for upflow, downflow, and horizontal installs
  • Accepts field-installed auxiliary heater kits with integral breakers
  • Less than 2% cabinet air leakage at 1-inch H2O per ASHRAE 193
  • Integrated A2L sensor and mitigation board

Specifications & Manuals

RA14AY Technical Specifications Rheem Condenser Brochure RA14AY Submittal Sheet RH2TY Technical Specifications RH2TY Installation Instructions RH2TY Submittal Sheet Rheem Warranty Certificate

Product documentation includes condenser and air handler technical specifications, submittal data, installation instructions, and warranty information to assist with equipment selection, permitting, installation, and service.