3.5 Ton Goodman 14.5 SEER2 R32 A/C System GLXS4BA4210, AMST42CU1300

Original price was: $4,536.00.Current price is: $453.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
54 People watching this product now!
Description

3.5 Ton Goodman 14.5 SEER2 R32 A/C System GLXS4BA4210, AMST42CU1300

This system fills the gap between 3 and 4 tons, where many larger homes land. It pairs the 42,000 BTU/h GLXS4BA4210 R-32 condenser with the AMST42CU1300 multi-position air handler (AHRI #214859880). Homeowners with open-concept living areas, bonus rooms over garages or strong afternoon sun often need more than 3 tons without the humidity trade-off of an oversized 4 ton. This package is built for them. It has a scroll compressor, a 14.5 SEER2 rating and cooling-only operation, with optional field-installed electric heat.

Is a 3.5 Ton Air Conditioning System the Right Size?

A 3.5 ton system supplies 42,000 BTU/h of nominal cooling. It’s commonly used in larger single-family homes, often somewhere near 1,800-2,100 sq. ft. as a rough guide. It’s the size to consider when a load calculation lands clearly above 3 tons but below 4.

Half-ton sizing matters most in humid climates. A system matched closely to the load runs longer, steadier cycles that pull more moisture from the air. Ceiling height, window area, insulation upgrades, duct leakage and even the number of people living in the home all affect whether 3.5 tons is the best choice.

Ideal for: Larger single-story homes, two-story homes with bonus rooms, open-concept floor plans and homes with significant west or south exposure.

Need more capacity? Step up to the 4 Ton Goodman R32 A/C System GLXS4BA4810, AMST48CU1300 for bigger homes with heavier cooling loads.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit GLXS4BA4210 – 3.5 Ton R32 Split System Air Conditioner
Indoor Air Handler AMST42CU1300 Multi-Position ECM Air Handler (C Cabinet, 21″ Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-32
Compressor Single-Stage Scroll Compressor with Advanced Copeland Technology
Metering Device Factory-Installed Internal Thermal Expansion Valve (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit – 19.0 MCA / 30A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase – 5.9 MCA / 15A Max Overcurrent (No Heat Kit)

The GLXS4BA4210 uses the large 35-1/2″ x 35-1/2″ GLXS4B cabinet at 35-3/4″ tall and 210 lbs, so plan for a pad sized to that footprint. Goodman recommends a 1-1/8″ suction line for a 25 ft. line set, while the service valve is 7/8″. Any adapter is field supplied. Pick up copper line sets and fittings in the right sizes before install day. The AMST42CU1300 shares the 21″ C cabinet with the 3 ton model but stands 53-7/16″ tall for its larger coil. For year-round electric heating, see the 3.5 ton Goodman R32 heat pump system GLZS4BA4210. The GLXS4BA4210 condenser is also sold separately.

Condensing Unit & Air Handler Features

GLXS4BA4210 Outdoor Condensing Unit

  • 42,000 BTU/h nominal cooling capacity
  • Single-stage scroll compressor with Advanced Copeland Technology
  • 72 dBA rated sound level
  • 1/6 HP PSC condenser fan motor with venturi airflow design
  • 83 oz. factory R-32 charge for 15 ft. of tubing
  • 3/8″ liquid and 7/8″ suction sweat service valves (1-1/8″ suction line recommended)
  • Factory-installed filter drier
  • Single-panel access to controls with room for field-installed accessories
  • Architectural Gray powder paint with 500-hour salt-spray approval
  • Meets 2023 Florida Building Code hurricane-wind requirements when anchored

AMST42CU1300 Multi-Position Air Handler

  • 42,000 BTU/h nominal capacity in a 21″ C cabinet
  • &#190 HP multi-speed ECM blower with nine speed taps
  • Internal TXV, ready for cooling and heat pump applications
  • All-aluminum evaporator coil
  • Upflow or horizontal, with a DFKE-02 downflow kit available
  • Cabinet air leakage under 2.0% at 1.0″ H₂O (ASHRAE 193)
  • Foil-faced insulation and screw-less sides limit sweating
  • Secondary drain connections on the thermoplastic drain pan
  • 19.5″ x 20″ filter with tool-less access
  • Field-installed HKTS heat kits available from 3 kW to 19 kW

Specifications & Manuals

GLXS4B Technical Specifications GLXS4 GLXS5 Installation Manual AMST R32 Technical Specifications AMST R32 Install Manual

Documentation covers GLXS4BA4210 refrigerant line sizing and electrical data, AMST42CU1300 airflow and heat kit data, cabinet dimensions and installation steps.