4 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump System RP14AY48AJ2NA, RH2TY4821STANNJ

Original price was: $4,310.00.Current price is: $431.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
70 People watching this product now!
Description

4 Ton Rheem 14.3 SEER2 R-454B Two Stage Heat Pump System RP14AY48AJ2NA, RH2TY4821STANNJ

Forty-eight thousand BTU of two-stage capacity, built for larger single-system homes. The RP14AY48AJ2NA outdoor heat pump drives the RH2TY4821STANNJ air handler at the top of that cabinet’s rating, delivering full four-ton output on R-454B refrigerant with a 27 amp minimum circuit ampacity. For builders and contractors working 2,000 to 2,400 square foot plans, this is the workhorse size of the Endeavor Line Classic Series.

Is a 4 Ton Heat Pump System the Right Size?

Four tons covers approximately 1,900 to 2,400 square feet in a hot climate. Larger four and five bedroom homes, houses with a lot of glass, and open-plan layouts with two-story great rooms commonly land here. It is also a common capacity for light commercial spaces such as offices, salons and small retail suites.

At this capacity, distribution becomes the deciding factor. A 4 ton system moves around 1,600 CFM, and a home that fights to deliver that airflow will feel uneven no matter how the equipment is rated. Long duct runs, a single undersized return, and closed interior doors all raise static pressure. If one part of the house is consistently warmer, zoning or a second smaller system is often a better answer than simply adding tonnage.

Ideal for: Four and five bedroom homes, open-plan houses with two-story great rooms, homes with extensive glass, and light commercial offices or retail suites in the 1,900 to 2,400 square foot range.

Need more capacity? Step up to the 5 Ton Rheem RP14AY60AJ2NA, RH2TY6024STANNJ Heat Pump System at 15.2 SEER2, or the narrower-cabinet 5 Ton RP14AY60AJ2NA, RH2TY6021STANAJ system when closet width is limited.

Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Heat Pump RP14AY48AJ2NA – 4 Ton / 48,000 BTU Two-Stage Heat Pump
Indoor Air Handler RH2TY4821STANNJ – 21.5 in. Wide Multiposition Air Handler
Application Residential and Light Commercial Split System Heat Pump
Refrigerant R-454B Low GWP (A2L)
Compressor Two-Stage Scroll
Rated Efficiency 14.3 SEER2 / 9.0 EER2 / 7.5 HSPF2 (Region IV)
AHRI Reference 214568778
Condenser Electrical 208/230V, Single Phase, 60 Hz – 27 MCA / 45 A Max Fuse or Breaker
Air Handler Electrical 208/240V, Single Phase, 60 Hz
Line Set Connections 3/8 in. Liquid, 7/8 in. Vapor

This match tops out the RH2TY4821STANNJ cabinet, so there is no headroom left indoors for a future capacity increase without changing air handlers. Plan the electrical accordingly, since the 45 amp maximum breaker is a step above the 3.5 ton system, and size auxiliary heat with a kit such as the 19.2 kW Rheem RXBH heat strip only after confirming fit and circuit capacity in the RH2TY tables.

Condenser & Air Handler Features

RP14AY48AJ2NA Outdoor Heat Pump

  • 48,000 BTU two-stage scroll compressor for large-home and light commercial loads
  • Two discrete capacity steps reduce on-off cycling on partial-load days
  • Inverted reversing valve with gravity-assist shifting for durable defrost operation
  • Expanded valve space and 15 in. corner access speed up charging and service calls
  • Individual louver panels can be removed for coil cleaning without full teardown
  • PlusOne Refrigerant Detection System combines the A2L sensor and mitigation board
  • Automatic outdoor unit shutdown if refrigerant is detected above threshold
  • Standard 24V control interface works with conventional two-stage heat pump thermostats
  • R-454B refrigerant delivers a 78 percent GWP reduction over previous generation refrigerants
  • 27 amp minimum circuit ampacity with 45 amp maximum overcurrent protection

RH2TY4821STANNJ Air Handler

  • 21.5 in. cabinet operating at the top of its 3.5 to 4 ton rating
  • 3/4 HP constant-torque ECM blower sized for approximately 1,600 CFM
  • Two-stage airflow profile follows compressor staging for quieter part-load operation
  • 7/8 in. vapor and 3/8 in. liquid sweat connections match the larger outdoor unit
  • Field-installed heat kits to 18.0 kW at 208V or 24.0 kW at 240V
  • Breakered heat kits satisfy UL and cUL service disconnect requirements
  • Upflow, downflow, horizontal left and horizontal right installation from one cabinet
  • Aluminum A-coil construction throughout for corrosion resistance
  • Foil-faced 1.0 in. insulation with verified sub-2 percent cabinet leakage
  • Onboard A2L detection shares the same architecture as the outdoor unit

Specifications & Manuals

RP14AY Technical Specifications Rheem RP14AY Brochure Rheem RP14AY RP15AY Installation Instructions Rheem RP14AY Submittal RH2TY Technical Specifications Rheem RH2TY RH1P Installation Instructions Rheem RH2TY Submittal Rheem Warranty

Specification and submittal documents for both the RP14AY outdoor unit and the RH2TY air handler are provided, along with installation instructions, the product brochure, and Rheem warranty terms. On commercial and permitted jobs, the submittal sheets carry the dimensional, weight and electrical data most inspectors and general contractors ask for.