1.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY18AJ1NA, RH2TY2417STANNJ

Original price was: $3,210.00.Current price is: $321.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
63 People watching this product now!
Description

1.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY18AJ1NA, RH2TY2417STANNJ

This 1.5 ton Rheem Endeavor Line matched system pairs the RA14AY18AJ1NA outdoor condenser with the RH2TY2417STANNJ two-stage air handler to deliver 18,000 BTU of cooling at 15.2 SEER2 on low-GWP R-454B refrigerant. It is the smallest capacity in the RA14AY lineup and the one most often specified for condominiums, garage conversions, room additions, and compact single-story homes where a larger system would short-cycle. The 17.5-inch air handler cabinet slips into the narrow utility closets common in older condo and apartment construction, and the factory-matched pairing carries AHRI certificate 215232472.

Is a 1.5 Ton Refrigeration System the Right Size?

A 1.5 ton system produces 18,000 BTU per hour of cooling. In most of the Southeast that translates to roughly 600 to 900 square feet of conditioned living space, though square footage alone is never the whole answer. This capacity is generally chosen for a one or two bedroom condo, a mother-in-law suite, a finished garage, or an addition served by its own dedicated duct run rather than tied into an existing trunk line.

Ceiling height, window area and orientation, attic insulation depth, duct location, shading, occupancy, and local design temperature all move the load calculation. Oversizing a small zone is a common mistake: a system with too much capacity satisfies the thermostat before it has run long enough to pull humidity out of the air, which leaves the space feeling cold and clammy. A Manual J load calculation is the reliable way to confirm 1.5 tons is correct before committing.

Ideal for: Condominiums, apartments, room additions, garage conversions, casitas, guest suites, and small single-story homes with a dedicated duct system.

Need more capacity? Step up to the 2 Ton Rheem 15.2 SEER2 R454B System RA14AY24BJ1NA, RH2TY2417STANNJ, which uses the same 17.5-inch air handler cabinet with a larger outdoor unit.

Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, duct design, window area, ceiling height, occupancy, and local design conditions. Run our AC tonnage and BTU calculator, request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit RA14AY18AJ1NA – 1.5 Ton Endeavor Line Classic Series Air Conditioner
Indoor Air Handler RH2TY2417STANNJ Two-Stage Multiposition Air Handler
Application Residential Split System, Cool Only with Field-Installed Electric Heat
Refrigerant R-454B
Nominal Capacity 18,000 BTU / 1.5 Tons
Rated Efficiency 15.2 SEER2
Air Handler Cabinet Width 17.5 inches
AHRI Reference Number 215232472
Electrical 208-230V, Single Phase, 60 Hz

Both halves of this package ship as a factory-matched, AHRI-certified pair. The RA14AY18AJ1NA and the RH2TY2417STANNJ each carry Rheem’s PlusOne Refrigerant Detection System, so the A2L sensor and mitigation board are already integrated rather than field-added. Electric heat kits, thermostats, and line sets are ordered separately to suit the installation.

Condensing Unit & Air Handler Features

RA14AY18AJ1NA Outdoor Condensing Unit

  • 1.5 ton nominal capacity rated at 15.2 SEER2
  • Engineered for low-GWP R-454B refrigerant
  • 7mm condenser copper coil reduces refrigerant charge requirements
  • PlusOne Triple Service Access with 15-inch corner service opening
  • Two-fastener removable corner panel for faster service calls
  • PlusOne Refrigerant Detection System integrated in a single box
  • Automatically pauses outdoor unit operation if excess refrigerant is detected
  • Compatible with any 24V thermostat application
  • Corrosion-resistant composite base pan and powder coat paint system
  • Curved louvered panels and rugged corner posts protect the coil

RH2TY2417STANNJ Air Handler

  • Two-stage airflow with constant torque ECM blower motor
  • Slim 17.5-inch cabinet fits narrow utility and hallway closets
  • 1.0 inch foil-faced cabinet insulation for quieter operation
  • Aluminum fins bonded to internally grooved aluminum tubing
  • Factory-installed thermal expansion valve
  • 4-way convertible: upflow, downflow, horizontal left, horizontal right
  • Rugged steel compact cabinet construction
  • Accepts field-installed auxiliary electric heater kits
  • Heater kits include circuit breakers meeting UL and cUL service disconnect requirements
  • Less than 2% cabinet air leakage at 1-inch H2O per ASHRAE Standard 193

Specifications & Manuals

RA14AY Technical Specifications Rheem Condenser Brochure RA14AY Submittal Sheet RH2TY Technical Specifications RH2TY Installation Instructions RH2TY Submittal Sheet Rheem Warranty Certificate

Product documentation includes condenser and air handler technical specifications, submittal data, installation instructions, and warranty information to assist with equipment selection, permitting, installation, and service.