3.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY42AJ1NA, RH2TY4821STANNJ

Original price was: $4,085.00.Current price is: $408.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
25 People watching this product now!
Description

3.5 Ton Rheem 15.2 SEER2 R454B Central System RA14AY42AJ1NA, RH2TY4821STANNJ

This 42,000 BTU Rheem Endeavor Line package marks the transition point in the RA14AY lineup: it is the first size to pair with the wider 21-inch RH2TY4821STANNJ air handler and its 3/4 HP ECM blower. The RA14AY42AJ1NA condenser holds a 15.2 SEER2 rating on low-GWP R-454B refrigerant under AHRI reference 215232971. Three and a half tons is the size that serves larger single-story homes and modest two-story houses that a 3 ton system leaves struggling on August afternoons.

Is a 3.5 Ton Refrigeration System the Right Size?

At 42,000 BTU per hour, a 3.5 ton system generally covers 1,800 to 2,100 square feet in a hot, humid climate. It is frequently the correct answer for four-bedroom single-story homes, homes with cathedral or tray ceilings that add conditioned volume without adding floor area, and houses with large unshaded glass on the south and west exposures.

This is also the point where duct capacity becomes the limiting factor more often than equipment capacity. The RH2TY4821STANNJ needs roughly 1,400 CFM to hit nominal, and a return system originally built for 3 tons will choke it. Before upsizing from 3 tons to 3.5, confirm that the return grille area, filter size, and trunk line can carry the additional airflow – otherwise the new system will run at higher static pressure and lose the efficiency you paid for.

Ideal for: Four-bedroom single-story homes, houses with vaulted or two-story great rooms, homes with large west-facing window walls, and small commercial suites.

Need more capacity? Step up to the 4 Ton Rheem 14.8 SEER2 R454B System RA14AY48AJ1NA, RH2TY4821STANNJ, which shares this same 21-inch air handler.

Recommended sizing ranges are general guidelines only. Actual system requirements depend on insulation, duct design, window area, ceiling height, occupancy, and local design conditions. Run our AC tonnage and BTU calculator, request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit RA14AY42AJ1NA – 3.5 Ton Endeavor Line Classic Series Air Conditioner
Indoor Air Handler RH2TY4821STANNJ Two-Stage Multiposition Air Handler
Application Residential Split System, Cool Only with Field-Installed Electric Heat
Refrigerant R-454B
Nominal Capacity 42,000 BTU / 3.5 Tons
Rated Efficiency 15.2 SEER2
Air Handler Cabinet Width 21 inches
AHRI Reference Number 215232971
Electrical 208-230V, Single Phase, 60 Hz

Plan the closet before the equipment arrives. Moving from the 17.5-inch cabinet used on 1.5 through 3 ton systems to this 21-inch chassis adds three and a half inches of width plus service clearance. On retrofits that often means widening a closet opening or reworking the supply plenum, and it is the single most common surprise on a 3 to 3.5 ton upsize.

Condensing Unit & Air Handler Features

RA14AY42AJ1NA Outdoor Condensing Unit

  • 3.5 ton nominal capacity, 42,000 BTU, rated 15.2 SEER2
  • Highest efficiency tier available in the RA14AY family
  • Low-GWP R-454B refrigerant, roughly 78% lower GWP than legacy blends
  • 7mm condenser copper coil for reduced charge and lighter cabinet
  • PlusOne Triple Service Access with 15-inch corner opening
  • Individual and two-fastener removable corner panels
  • Patented one-box PlusOne Refrigerant Detection System
  • Automatic outdoor unit shutdown on refrigerant detection
  • Composite base pan resists rust at the most failure-prone surface
  • 10-year conditional parts warranty with Rheem registration

RH2TY4821STANNJ Air Handler

  • 21-inch cabinet covering 3.5 and 4 ton applications
  • 3/4 HP constant torque ECM blower motor
  • Two-stage airflow with multiple selectable speed taps
  • 1.0 inch foil-faced insulation for quieter operation at higher CFM
  • All-aluminum coil with internally grooved tubing
  • Factory thermal expansion valve matched to R-454B
  • 4-way convertible for upflow, downflow, and horizontal applications
  • Field-installed heater kits with UL and cUL compliant breakers
  • Rugged steel cabinet with under 2% leakage at 1-inch H2O
  • Integrated A2L sensor and mitigation board, no field kit required

Specifications & Manuals

RA14AY Technical Specifications Rheem Condenser Brochure RA14AY Submittal Sheet RH2TY Technical Specifications RH2TY Installation Instructions RH2TY Submittal Sheet Rheem Warranty Certificate

Product documentation includes condenser and air handler technical specifications, submittal data, installation instructions, and warranty information to assist with equipment selection, permitting, installation, and service.