5 Ton Goodman 14 SEER2 R32 A/C System GLXS4BA6010, AMST60DU1300

Original price was: $5,470.00.Current price is: $547.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
70 People watching this product now!
Description

5 Ton Goodman 14 SEER2 R32 A/C System GLXS4BA6010, AMST60DU1300

The flagship capacity of the GLXS4B R-32 series pairs the 60,000 BTU/h GLXS4BA6010 condenser with the D-cabinet AMST60DU1300 air handler (AHRI #214860141, 14 SEER2). This is the maximum-capacity single-phase package in the lineup. It’s built for owners of very large homes, and for single-phase light commercial spaces like small offices, studios and retail suites that need serious cooling from one split system. Unlike the smaller GLXS4B units, it’s the only one with an ECM condenser fan motor. The air handler adds a 1 HP ECM blower and supports heat kits up to 25 kW.

Is a 5 Ton Air Conditioning System the Right Size?

At 60,000 BTU/h, 5 tons is the upper limit for most single-phase residential split systems. It’s typically considered for large homes, often around 2,500-3,000 sq. ft. or more as a rough reference, or for light commercial spaces with high internal loads. Because it’s the largest size, oversizing mistakes are costly: bigger ducts, higher electrical service and humidity problems if the load isn’t really there.

Confirm the load with a Manual J (residential) or a commercial load calculation. Check that the duct system can carry 5 ton airflow, and verify the electrical panel has room for a 50A condenser circuit plus the air handler and any heat kit. Very large homes are sometimes better served by two smaller zoned systems, and our team can help you compare.

Ideal for: Large single-family homes, high-ceiling custom homes, single-phase small offices, studios and retail suites with high cooling demand.

Want higher efficiency? Compare the 5 Ton Goodman 16.2 SEER2 R32 A/C System GLXS5BA6010, AMST60DU1300, which uses the same air handler with a higher-efficiency GLXS5 condenser.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit GLXS4BA6010 – 5 Ton R32 Split System Air Conditioner
Indoor Air Handler AMST60DU1300 Multi-Position ECM Air Handler (D Cabinet, 24.5″ Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-32
Compressor Single-Stage Scroll Compressor with Advanced Copeland Technology
Metering Device Factory-Installed Internal Thermal Expansion Valve (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit – 32.4 MCA / 50A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase – 8.6 MCA / 15A Max Overcurrent (No Heat Kit)

The GLXS4BA6010 is the tallest condenser in the series at 35-1/2″ x 35-1/2″ x 39-1/2″ and 224 lbs, with a 1/3 HP ECM fan motor and a 94 oz. factory charge. Set it on a pad sized for its footprint. Hurricane-zone installs should use proper tie-downs from our condenser pads, wall mounts and tie-downs selection. The AMST60DU1300 steps up to the 24.5″ D cabinet (58″ tall, 24-5/8″ deep) with an 11″ x 10″ blower wheel. Replacing just the outdoor unit? The 5 ton GLXS4BA6010 condenser is sold separately. The 5 ton Goodman R32 heat pump system GLZS4BA6010 is available if you want heat pump heating.

Condensing Unit & Air Handler Features

GLXS4BA6010 Outdoor Condensing Unit

  • 60,000 BTU/h nominal cooling, the largest in the GLXS4B series
  • Single-stage scroll compressor with Advanced Copeland Technology
  • 1/3 HP ECM condenser fan motor, the only ECM fan in the series
  • 76 dBA rated sound level
  • 94 oz. factory R-32 charge for 15 ft. of tubing
  • 1-1/8″ suction line recommended (7/8″ service valve; adapter field supplied)
  • Factory-installed filter drier and high-pressure switch
  • Extended-life capacitors and enclosed contactor
  • Top and side maintenance access
  • 2023 Florida Building Code hurricane-wind compliant when properly anchored

AMST60DU1300 Multi-Position Air Handler

  • 60,000 BTU/h nominal capacity in a 24.5″ D cabinet
  • 1 HP direct drive, multi-speed ECM blower with 11″ x 10″ wheel
  • Internal factory-installed TXV
  • All-aluminum evaporator coil optimized for R-32
  • Upflow or horizontal, with a DFKE-03 downflow kit available
  • Rigid SmartFrame cabinet with glue-less insulation retention
  • Foil-faced internal insulation and screw-less sides and back
  • Tool-less access to a 23″ x 20″ filter
  • Accepts HKTS electric heat kits from 3 kW up to 25 kW
  • AHRI certified, ETL listed and UL 60335-2-40 compliant

Specifications & Manuals

GLXS4B Technical Specifications GLXS4 GLXS5 Installation Manual AMST R32 Technical Specifications AMST R32 Install Manual

Documentation includes GLXS4BA6010 electrical, charge and line-size data, AMST60DU1300 D-cabinet dimensions, airflow tables, single-point wiring and heat kit data up to 25 kW.