2.5 Ton Rheem 15.2 SEER2 R454B Central System RA15AY30AJ1NA, RH2TY3617STANNJ

Original price was: $3,670.00.Current price is: $367.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
20 People watching this product now!
Description

2.5 Ton Rheem 15.2 SEER2 R454B Central System RA15AY30AJ1NA, RH2TY3617STANNJ

This Rheem Endeavor Line Classic system combines the RA15AY30AJ1NA condenser with the RH2TY3617STANNJ two-stage-airflow air handler, AHRI certified at 15.2 SEER2 (#215270465). It delivers 30,000 BTU/h on low-GWP R-454B refrigerant, with Rheem’s PlusOne Refrigerant Detection System in the air handler to pause the outdoor unit if a leak is found. From 2.5 tons up, the RA15AY adds Rheem’s Swept Wing fan blade for quieter airflow. It’s cooling only, with optional Rheem electric heat strips.

Is a 2.5 Ton Air Conditioning System the Right Size?

A 2.5 ton system delivers 30,000 BTU/h of nominal cooling. It’s commonly used in 2- to 3-bedroom homes, often around 1,200-1,500 sq. ft. as a rough reference. That range shifts a lot with climate and construction.

West-facing glass, vaulted ceilings, older windows and leaky attic ducts can push a home toward 3 tons, while a tight, well-insulated home may need less. A Manual J load calculation gives a reliable answer before you buy.

Ideal for: 2- to 3-bedroom single-family homes, townhomes and mid-size ranch homes.

Need more capacity? Step up to the 3 Ton Rheem 15.2 SEER2 R454B Central System RA15AY36AJ1NA, RH2TY3617STANNJ, which uses the same air handler.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit RA15AY30AJ1NA – 2.5 Ton Rheem Classic R454B Air Conditioner
Indoor Air Handler RH2TY3617STANNJ Two-Stage Airflow Multipoise Air Handler (17.5″ Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-454B (Low-GWP A2L Refrigerant)
Compressor Single-Stage Scroll Compressor
Metering Device Factory-Installed Expansion Valve on Indoor Coil (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit – 17 MCA / 25A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase – 3 MCA / 15A Max Overcurrent (No Heat Kit)

The RA15AY30AJ1NA condenser stands 27″ tall on a 33.75″ x 33.75″ base and weighs 190 lbs, with a 24″ Swept Wing fan and a 71 dBA sound rating. The RH2TY3617STANNJ air handler is 17.5″ wide and 42.5″ tall, with a 1/2 HP motor and 10″ x 10″ blower. Compare the 2.5 ton Rheem Select WA14AY30AJ1NA system if you’d like to see the Select series option.

Condensing Unit & Air Handler Features

RA15AY30AJ1NA Outdoor Condensing Unit

  • 30,000 BTU/h nominal cooling capacity
  • Single-stage scroll compressor
  • 71 dBA weighted sound power rating
  • 2-row 7 mm copper tube coil for efficient heat transfer
  • 92 oz. factory R-454B charge for 15 ft. of line set
  • 24″ Swept Wing fan with 1/6 HP motor
  • 3/8″ liquid and 3/4″ suction front-seating service valves
  • PlusOne Expanded Valve Space and Triple Service Access
  • Internal pressure relief valve and internal thermal overload
  • 10-year conditional parts limited warranty (registration required)

RH2TY3617STANNJ Two-Stage Air Handler

  • Two-stage airflow with a constant torque (ECM) motor
  • 1/2 HP, 5-speed motor with 10″ x 10″ blower
  • PlusOne Refrigerant Detection System with integrated A2L sensor
  • Aluminum fins bonded to internally grooved aluminum tubing
  • 4-way convertible: upflow, downflow, horizontal left or right
  • 1.0″ foil-faced cabinet insulation for quieter operation
  • Cabinet air leakage under 2% at 1″ H₂O (ASHRAE 193)
  • Works with any standard 24V thermostat
  • Expansion valve on indoor coil for AC or heat pump use
  • Field-installed 5, 8 and 10 kW heater kits with UL/cUL-listed breakers

Specifications & Manuals

RA15AY Technical Specifications RH2TY Technical Specifications Rheem RH2TY RH1P Installation Instructions Rheem Warranty

Documentation includes RA15AY electrical, charge and dimensional data, RH2TY3617 airflow and heater tables, air handler installation instructions and the Rheem limited warranty.