60 Amp Non-Fused Pull-Out AC Disconnect – NEMA 3R Outdoor Rated

Original price was: $36.00.Current price is: $10.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
21 People watching this product now!
Description

A/C Disconnect 60 Amp Non-Fused Pull-Out Style

A heavy-duty 60 amp non-fused pull-out disconnect built for outdoor HVAC service shutoff. Housed in a NEMA 3R rainproof, powder-coated steel enclosure, this top-opening disconnect box gives HVAC installers, contractors, and service technicians a fast, code-compliant way to cut power to air conditioning condensers and heat pumps at the equipment.

Is a 60 Amp Non-Fused Disconnect the Right Choice?

A non-fused disconnect provides a local, visible means of disconnect at the outdoor unit without adding overcurrent protection at the box itself. It’s the right fit when the circuit’s overcurrent protection is already handled upstream at the panel or breaker, and you simply need a code-required service disconnect within sight of the equipment.

The 60 amp rating covers the maximum load this disconnect is designed to carry. Choosing the correct disconnect depends on the equipment’s minimum circuit ampacity and maximum overcurrent protection rating, the conductor size, and whether local code calls for a fused or non-fused device. Always confirm the requirement against the unit’s nameplate and the installing jurisdiction.

Ideal for: Residential and light-commercial AC condensers, heat pumps, and other outdoor HVAC equipment rated at or below 60 amps that require a local service disconnect.

Need a three-phase option? Step up to the Square D 60A 3-Phase Non-Fusible Disconnect for three-phase commercial installations.

Recommended applications are general guidelines only. Actual requirements depend on equipment nameplate ratings, conductor sizing, and local electrical code. Request a quote, contact Budget Heating, or call 813-885-7999.

What’s Included

Type 60 Amp Non-Fused Pull-Out AC Disconnect
Max Amperage 60A
Enclosure Rating NEMA 3R (Rainproof) – Outdoor Use
Construction Powder-Coated Steel
Conductor Compatibility Copper or Aluminum (Copper-Rated Load Lugs)
Access Top-Opening Lift-Up Cover with Lockable Latch
Knockouts Back, Bottom, and Sides
Listing UL Listed
Dimensions 8-13/16″ H × 5-7/16″ W × 3-3/16″ D (225 × 138.5 × 80 mm)

Each disconnect ships individually boxed and ready to mount beside the outdoor unit for a clean, code-compliant service installation.

Enclosure & Electrical Features

Enclosure & Construction

  • NEMA 3R rainproof enclosure rated for outdoor installation
  • Powder-coated steel resists corrosion and weather exposure
  • Top-opening lift-up cover for convenient wiring access
  • Lockable latch supports lockout/tagout and added security
  • Knockouts on back, bottom, and sides for flexible conduit entry
  • Compact footprint mounts easily beside condensing units

Electrical & Installation

  • 60A maximum load rating
  • Non-fused pull-out design for fast service shutoff
  • Copper-rated load lugs accept copper or aluminum conductors
  • UL Listed for code-compliant installations
  • Pull-out block fully removes power for safe maintenance
  • Purpose-built as a service disconnect for AC and heat pump systems