2 Ton Rheem 16 SEER2 R454B Central System RA15AY24AJ1NA, RH2TY2417STANNJ

Original price was: $3,595.00.Current price is: $359.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
21 People watching this product now!
Description

2 Ton Rheem 16 SEER2 R454B Central System RA15AY24AJ1NA, RH2TY2417STANNJ

This 2 ton Rheem Endeavor Line Classic system matches the RA15AY24AJ1NA condenser with the RH2TY2417STANNJ two-stage-airflow air handler. It’s AHRI certified at 16 SEER2 (#215261707). At 69 dBA, the RA15AY24 carries the lowest sound rating in the RA15AY line, a plus for homes where the condenser sits near a bedroom or patio. It uses low-GWP R-454B with Rheem’s PlusOne Refrigerant Detection System built into the air handler. It’s cooling only, with optional Rheem electric heat strips for backup heat.

Is a 2 Ton Air Conditioning System the Right Size?

Two tons (24,000 BTU/h) suits moderate cooling loads. That often means 2-bedroom homes, larger condos and starter homes around 900-1,200 sq. ft. as a general reference. Two homes with the same square footage can still need different tonnage.

Orientation, window glass, ceiling height, insulation and duct leakage all shape the actual load. Replacing an old system with the same tonnage without checking can carry an original sizing mistake forward. A Manual J load calculation is the best way to confirm 2 tons.

Ideal for: Starter homes, 2-bedroom houses, larger condos, rentals and homes where outdoor noise is a concern.

Need more capacity? Step up to the 2.5 Ton Rheem 15.2 SEER2 R454B Central System RA15AY30AJ1NA, RH2TY3617STANNJ for a larger load.

Recommended home sizes are general guidelines only. Actual system requirements depend on insulation, climate, windows, ductwork, occupancy and a proper load calculation. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Condensing Unit RA15AY24AJ1NA – 2 Ton Rheem Classic R454B Air Conditioner
Indoor Air Handler RH2TY2417STANNJ Two-Stage Airflow Multipoise Air Handler (17.5″ Wide)
Application Cooling-Only Central Air Split System (Electric Heat Kit Optional)
Refrigerant R-454B (Low-GWP A2L Refrigerant)
Compressor Single-Stage Scroll Compressor
Metering Device Factory-Installed Expansion Valve on Indoor Coil (TXV)
Electrical 208/230V, Single Phase, 60 Hz Condensing Unit – 13 MCA / 20A Max Overcurrent
Air Handler Electrical 208/240V, Single Phase – 3 MCA / 15A Max Overcurrent (No Heat Kit)

The RA15AY24AJ1NA condenser sits in a 25″ tall cabinet on a 33.75″ x 33.75″ base and weighs 178 lbs. It has a 24″ fan with a 1/6 HP motor and ships with a 112 oz. R-454B charge. The RH2TY2417STANNJ air handler is 17.5″ wide and 42.5″ tall and converts for upflow, downflow or horizontal installs. For better comfort control, compare the 2 ton Rheem 16 SEER2 two-stage system RA16AY24AJ2NA.

Condensing Unit & Air Handler Features

RA15AY24AJ1NA Outdoor Condensing Unit

  • 24,000 BTU/h nominal cooling capacity
  • Single-stage scroll compressor
  • 69 dBA weighted sound power rating
  • 2-row 7 mm copper tube coil for efficient heat transfer
  • 112 oz. factory R-454B charge for 15 ft. of line set
  • 24″ fan with 1/6 HP motor
  • 3/8″ liquid and 3/4″ suction front-seating service valves
  • PlusOne Expanded Valve Space and Triple Service Access
  • Internal pressure relief valve and internal thermal overload
  • 10-year conditional parts limited warranty (registration required)

RH2TY2417STANNJ Two-Stage Air Handler

  • Two-stage airflow with a constant torque (ECM) motor
  • 1/3 HP, 5-speed motor with 10″ x 8″ blower
  • PlusOne Refrigerant Detection System with integrated A2L sensor
  • Aluminum fins bonded to internally grooved aluminum tubing
  • 4-way convertible: upflow, downflow, horizontal left or right
  • 1.0″ foil-faced cabinet insulation for quieter operation
  • Cabinet air leakage under 2% at 1″ H₂O (ASHRAE 193)
  • Works with any standard 24V thermostat
  • Expansion valve on indoor coil for AC or heat pump use
  • Field-installed 5, 8 and 10 kW heater kits with UL/cUL-listed breakers

Specifications & Manuals

RA15AY Technical Specifications RH2TY Technical Specifications Rheem RH2TY RH1P Installation Instructions Rheem Warranty

Documentation includes RA15AY electrical, sound and dimensional data, RH2TY airflow and heater tables, air handler installation instructions and the Rheem limited warranty.