3.5 Ton Rheem 14.3 SEER2 R454B Two Stage Heat Pump System RP14AY42AJ2NA, RH2TY4821STANNJ

Original price was: $3,975.00.Current price is: $397.99.

Clothing Size Conversion Chart
Category US EU UK Chest (in) Waist (in) Hips (in)
Men XS 44 34 32-34 26-28 33-35
S 46 36 34-36 28-30 35-37
M 48 38 38-40 32-34 39-41
L 50 40 42-44 36-38 43-45
XL 52 42 46-48 40-42 47-49
Women XS 32 6 31-32 24-25 33-34
S 34 8 33-34 26-27 35-36
M 36 10 35-36 28-29 37-38
L 38-40 12-14 37-39 30-32 39-41
XL 42 16 40-42 33-35 42-44
Youth XS 128 7 26-28 23-24 26-28
S 134 8 28-30 24-25 28-30
M 140 10 30-32 25-26 30-32
L 146 12 32-34 26-27 32-34
XL 152 14 34-36 27-28 34-36
Pants Size Conversion Chart
CategoryUSEUUKWaist (in)Hip (in)Inseam (in)
Men284428283430
304630303631
324832323832
345034344033
365236364234
Women0324243430
2346253530
4368263631
63810273832
84012284032
Shoes Size Conversion Chart
CategoryUSEUUKFoot Length (in)
Men6395.59.25
7406.59.625
8417.510
9428.510.25
10439.510.625
114410.511
124511.511.25
134612.511.625
Women5352.58.5
6363.58.875
7374.59.25
8385.59.625
9396.510
10407.510.25
11418.510.625
12429.511
M (Unisex)5374.58.75
6385.59
7396.59.5
8407.510
9418.510.25
10429.510.625
114310.511
124411.511.25
25 People watching this product now!
Description

3.5 Ton Rheem 14.3 SEER2 R-454B Two Stage Heat Pump System RP14AY42AJ2NA, RH2TY4821STANNJ

The 3.5 ton match is the crossover point in the RP14AY lineup. The RP14AY42AJ2NA outdoor unit delivers 42,000 BTU, and the pairing moves to the RH2TY4821STANNJ, a 21.5 inch wide air handler with a 3/4 HP blower and a 7/8 inch vapor connection. Everything downstream changes with it: wider return, larger filter, bigger line set and a heat kit range that reaches 24 kW. This is the size where a home stops being a small house and starts being a real airflow project.

Is a 3.5 Ton Heat Pump System the Right Size?

A 3.5 ton system supplies 42,000 BTU per hour, generally matching 1,700 to 2,100 square feet in the Southeast. Two-story homes with a single zoned system, four-bedroom houses with vaulted ceilings, and homes with large west-facing glass frequently calculate here rather than at 3 tons.

The practical question at this capacity is rarely the compressor; it is whether the duct system can move roughly 1,400 CFM. Returns sized for a 3 ton system will run high static, drive up blower watts and cut delivered capacity. Before stepping up from 3 tons, check total return free area, trunk sizing and filter face velocity. If the ducts cannot be improved, a two-stage system like this one at least spends most of its run time at lower airflow where the existing ducts perform better.

Ideal for: Two-story homes on a single system, four-bedroom houses with vaulted or cathedral ceilings, homes with heavy western exposure, and small commercial suites in the 1,700 to 2,100 square foot range.

Need more capacity? Step up to the 4 Ton Rheem RP14AY48AJ2NA, RH2TY4821STANNJ Heat Pump System, which adds 6,000 BTU using the same 21.5 in. air handler.

Recommended capacity ranges are general guidelines only. Actual system requirements depend on insulation, window area, duct design, air infiltration, and local climate. Request free sizing assistance, contact Budget Heating, or call 813-885-7999.

What’s Included

Outdoor Heat Pump RP14AY42AJ2NA – 3.5 Ton / 42,000 BTU Two-Stage Heat Pump
Indoor Air Handler RH2TY4821STANNJ – 21.5 in. Wide Multiposition Air Handler
Application Residential Split System Heat Pump, Heating and Cooling
Refrigerant R-454B Low GWP (A2L)
Compressor Two-Stage Scroll
Rated Efficiency 14.3 SEER2 / 9.0 EER2 / 7.5 HSPF2 (Region IV)
AHRI Reference 214568774
Condenser Electrical 208/230V, Single Phase, 60 Hz – 24 MCA / 40 A Max Fuse or Breaker
Air Handler Electrical 208/240V, Single Phase, 60 Hz
Line Set Connections 3/8 in. Liquid, 7/8 in. Vapor

Note the vapor line change: 3.5 ton and larger RP14AY matches use 7/8 in. suction tubing, so a 25 ft. 7/8 in. x 3/8 in. copper line set is the correct starting point rather than the 3/4 in. sets used on the smaller systems. Auxiliary heat is added separately, such as a 15 kW Rheem RXBH heat strip, with kit selection confirmed against the RH2TY tables.

Condenser & Air Handler Features

RP14AY42AJ2NA Outdoor Heat Pump

  • 42,000 BTU two-stage scroll compressor bridging the 3 and 4 ton capacities
  • High stage reserved for design-day extremes, low stage for everyday load
  • Larger condenser coil than the 3 ton model for improved head pressure control on hot days
  • Inverted reversing valve reduces stress on brazed joints during defrost
  • 15 in. corner service access with a two-fastener removable panel
  • PlusOne Expanded Valve Space accommodates recovery machines and larger gauges
  • PlusOne Refrigerant Detection System integrated into a single board and sensor assembly
  • Operates on standard 24V thermostat wiring with two-stage heat pump control
  • R-454B refrigerant compliant with the 2025 EPA 700 GWP limit
  • 24 amp minimum circuit ampacity with 40 amp maximum overcurrent protection

RH2TY4821STANNJ Air Handler

  • 21.5 in. wide cabinet with the larger coil needed above 3 tons
  • 3/4 HP constant-torque ECM blower for higher airflow at real-world duct static
  • Rated for 3.5 to 4 ton applications, allowing a future capacity change without a new cabinet
  • 7/8 in. vapor and 3/8 in. liquid sweat connections
  • Accepts field-installed electric heat kits up to 18.0 kW at 208V or 24.0 kW at 240V
  • Heat kits include circuit breakers meeting UL and cUL service disconnect requirements
  • Four-way convertible: upflow, downflow, horizontal left and horizontal right
  • Aluminum fin and internally grooved aluminum tube coil for corrosion resistance
  • 1.0 in. foil-faced insulation with under 2 percent cabinet leakage per ASHRAE 193
  • Integrated A2L refrigerant detection and automatic system shutdown on a leak event

Specifications & Manuals

RP14AY Technical Specifications Rheem RP14AY Brochure Rheem RP14AY RP15AY Installation Instructions Rheem RP14AY Submittal RH2TY Technical Specifications Rheem RH2TY RH1P Installation Instructions Rheem RH2TY Submittal Rheem Warranty

Because this is the size where cabinet width, line set diameter and heat kit capacity all change, the submittal sheets and installation instructions are worth reviewing before the job is quoted. The documents above include rating tables, dimensional and electrical data, installation procedures for both units, product literature, and Rheem warranty terms.